Activity

  • pati520gii posted an update 2 weeks ago

    3 Phase 2kW 3kW Grid Tie PV Inverter
    Product Description
    Specifications
    ModelSE 2KTLSE 3KTLSE 4KTLSE 5KTL
    EfficiencyAvailable
    Max. Efficiency97.80%97.80%98.00%98.00%
    European Efficiency97.00%97.00%97.40%97.40%
    Input(DC)
    Max. Input Power2,200W3,300W4,400W5,500W
    Max. Input Voltage600V600V600V600V
    Max. Input Current12.5A12.5A20.8A(2*10.4A)20.8A(2*10.4A)
    Min. Operating Voltage90V90V90V90V
    MPPT Operating Voltage Ranger70V-580V70V-580V70V-580V70-580V
    MPPT Operating Voltage Ranger(Full-Load)200V-520V240V-520V200V-520V240V-520V
    Max. Number of PV Strings1122
    No. of MPPTs1122
    Output(AC)
    Rated AC Active Power2,000W3,000W4,000W5,000W
    Max. AC Apparent Power2,100VA3,150VA4,200VA5,250VA
    Max. AC Active Power (PF=1)2,100W3,150W4,200W5,250W
    Max. AC Output Current9.5A14.3A19.0A23.6A
    Rated AC Voltage220V/230V,L+N+PE220V/230V,L+N+PE220V/230V,L+N+PE220V/230V,L+N+PE
    AC Voltage Range*180V-242V180V-242V180V-242V180V-242V
    Rated Grid Frequency50Hz/60Hz50Hz/60Hz50Hz/60Hz50Hz/60Hz
    Grid Frequency Range**45Hz-55Hz/55Hz-65Hz45Hz-55Hz/55Hz-65Hz45Hz-55Hz/55Hz-65Hz45Hz-55Hz/55Hz-65Hz
    THDI<3%<3%<3%<3%
    DC Current Injection<0.5%ln<0.5%ln<0.5%ln0.99 Rated power (adjustable range 0.8 lead – 0.8 hysteresis)
    Protection
    Input DC switchoptional
    Anti-islanding protectionsupport
    AC overcurrent protectionsupport
    AC short circuit protectionsupport
    DC reverse connectionsupport
    Anti-surge protectionsupport
    Insulation resistance detectionsupport
    Leakage current protectionsupport
    General
    TopologyTransformerless
    IP RatingIP65
    CoolingNatural coolin
    Operating Temperature Range-25℃-60℃
    Relative Humidity Range0-100%
    Max. Operating Altitude4000m
    Noise<25dB
    Dimensions(W*H*D)285mm*336mm*125mm335mm*426mm*125mm
    Weight8.8KG12.8KG
    HMI&COM
    DisplayBlue-tooth & LED Indicator
    CommunicationRS485(option), WIFI(optional), GPRS(optional)
    Certification
    SafetyIEC62109-1, IEC62109-2, NB/T32004
    EMCEN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
    Grid CodeNB/T32004, VDE-AR-N 4105, IEC 61727, AS4777
    PRODUCT DETAIL
    PRODUCT ADVANTAGE
    APPLICATION
    PRODUCTION LINE
    CERTIFICATE
    This product support custom development with fully your own logo
    Main Export Markets
    Eastern Europe
    North America
    Mid East/Africa
    Central/South America
    Asia
    Western Europe
    Australasia
    FAQ
    1. Q: Can the motor(3ph. 200 volts) adjust the output voltage?
    A: Our VFD output voltage is 220V,so it can work with your 3ph. 200 volts.
    2. Q: How do I wire start stop button to VFD? I see x1-x5 but am clueless how to do it.
    A: When you complete a circuit between x1 – x5 and "common", whatever is programmed for x1 – x5 will be executed (ie. start, stop etc..) You will also need to set the unit for terminal control (I don't know the command number off hand). By setting the unit to terminal control, you will no longer be able to start and stop your machine directally from the VFD.
    3. Q: Does this thing need to be mounted in an electrical cabinet, or can I safely mount it to the side of a piece of equipment?
    A: Yes,you can mount it in a box or just put it outsidePV Inverter Made in China
    website:http://www.soyan-tech.com/inverter/pv-inverter/